EasyManua.ls Logo

Alcatel-Lucent 7750 - Page 376

Alcatel-Lucent 7750
788 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Interfaces
Page 376 7750 SR Interface Configuration Guide
===============================================================================
Description : OC-48 SONET/SDH
Interface : 2/2/2 Speed : oc48
Admin Status : up Oper Status : up
Physical Link : Yes Loopback Mode : none
Single Fiber Mode : No
APS Group : none APS Role : none
Clock Source : loop Framing : sonet
Last State Change : 04/11/2007 14:53:53 Port IfIndex : 37814272
J0 String : 0x01 Section Trace Mode : byte
Rx S1 Byte : 0x00 (stu) Rx K1/K2 Byte : 0x00/0x00
Tx S1 Byte : 0x0f (dnu) Tx DUS/DNU : disabled
Rx J0 String (Hex) : af 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
Cfg Alarm : loc lrdi lb2er-sf slof slos
Alarm Status :
Hold time up : 500 milliseconds
Hold time down : 0 milliseconds
Transceiver Data
Transceiver Type : SFP
Model Number : SFP-OC48-SR1
Transceiver Code : OC48 SR
Laser Wavelength : 1310 Diag Capable : yes
Connector Code : LC Vendor OUI : 00:01:9c
Manufacture date : 2004/08/20 00:00:00 Media : SONET/SDH
Serial Number : 6331000705
Part Number : CT2-MS1LBTD32Z2
Optical Compliance*: 00:01:00:00:00:00:00:00
Link Len 9u : 2 kms Link Len Cu : 0 m
Link Len 9u : 20 * 100m Link Len 62.5u : 0 * 10m
Link Len 50u : 0 * 10m
===============================================================================
Port Statistics
===============================================================================
Input Output
-------------------------------------------------------------------------------
Packets 3870094 6656408
Discards 0 0
Unknown Proto Discards 0
===============================================================================
A:NS044050253#
wtr-annexb
Syntax wtr-annexb minutes
Context config>port>aps
Description This command waits to restore for Annex B mode operation. The delay after which the newly active section
becomes the primary section after a switch-over from the primary section to the secondary section occurs
and the switch request clears normally.
Parameters minutes — Specify the time, in minutes, to wait to restore for Annex B mode operation