Interface Configuration
7750 SR Interface Configuration Guide Page 597
Sample Output
B:Dut-D# show card
===============================================================================
Card Summary
===============================================================================
Slot Provisioned Equipped Admin Operational
Card-type Card-type State State
-------------------------------------------------------------------------------
1 iom-20g iom-20g up up
2 iom-20g iom-20g up up
A sfm-400g sfm-200g up up/standby
B sfm-400g sfm-200g up up/active
===============================================================================
B:Dut-D#
B:Dut-D# show card A detail
===============================================================================
Card A
===============================================================================
Slot Provisioned Equipped Admin Operational
Card-type Card-type State State
-------------------------------------------------------------------------------
A sfm-400g sfm-200g up up/standby
BOF last modified : N/A
Config file version :
Config file last modified : N/A
Config file last saved : N/A
CPM redundancy status : standby ready
Operational
state
Up — The card is operationally up.
Down — The card is operationally down.
Time of last
boot
The date and time the most recent boot occurred.
Current alarm
state
Displays the alarm conditions for the specific board.
Status Displays the current status.
Temperature Internal chassis temperature.
Temperature
threshold
The value above which the internal temperature must rise in order to
indicate that the temperature is critical.
Software boot
version
The version of the boot image.
Memory capacity The total amount of memory.
Label Description (Continued)