EasyManua.ls Logo

Alcatel-Lucent 7750 - Page 621

Alcatel-Lucent 7750
788 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Interface Configuration
7750 SR Interface Configuration Guide Page 621
Port : 1/1/1
Application : Egress Pool Name : PoolVoice
Resv CBS : 50% Policy Name : Port1-1-1
-------------------------------------------------------------------------------
Queue-Groups
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
Utilization State Start-Avg Max-Avg Max-Prob
-------------------------------------------------------------------------------
High-Slope Down 70% 90% 80%
Low-Slope Down 50% 75% 80%
Time Avg Factor : 7
Pool Total : 64 KB
Pool Shared : 32 KB Pool Resv : 32 KB
-------------------------------------------------------------------------------
Pool Resv CBS Provisioned Rising Falling Alarm
%age All Queues Alarm Thd Alarm Thd Color
-------------------------------------------------------------------------------
40% 300KB 350KB 250KB Amber
Pool Total In Use : 0 KB
Pool Shared In Use : 0 KB Pool Resv In Use : 0 KB
WA Shared In Use : 0 KB
Hi-Slope Drop Prob : 0 Lo-Slope Drop Prob : 0
-------------------------------------------------------------------------------
Name Tap FC-Maps MBS HP-Only A.PIR A.CIR
CBS Depth O.PIR O.CIR
-------------------------------------------------------------------------------
1->1/1/1:10->3
nc 128 KB 16 KB 100000 0
0 KB 0 Max 0
===============================================================================
*A:ALU-2011#
When alarm information is pending:
*A:Dut-T# show pools 4/1/1 access-ingress
===============================================================================
Pool Information
===============================================================================
Port : 4/1/1
Application : Acc-Ing Pool Name : default
CLI Config. Resv CBS : 10%
Resv CBS Step : 1% Resv CBS Max : 35%
Amber Alarm Threshold: 10% Red Alarm Threshold: 0%
-------------------------------------------------------------------------------
Queue-Groups
-------------------------------------------------------------------------------
Utilization State Start-Avg Max-Avg Max-Prob
-------------------------------------------------------------------------------
High-Slope Down 70% 90% 80%
Low-Slope Down 50% 75% 80%
Time Avg Factor : 7
Pool Total : 66048 KB
Pool Shared : 46080 KB Pool Resv : 19968 KB
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
Current Resv CBS Provisioned Rising Falling Alarm