Chapter 5
Programming Parameters
5–25
File 2 – Communications I/O
Channel A Group Logic Group Analog Input Group Analog Output Group
CntrlNet In 0 322 ChA Logic Cmd In 367 Analog In 1 339 Analog Out 1 387
CntrlNet In 1 323 Logic Command 52 An In 1 Offset 392 An Out 1 Offset 400
CntrlNet In 2 324 Logic Status Low 56 An In 1 Scale 393 An Out 1 Scale 401
CntrlNet In 3 325 Logic Status Hi 57 Analog In 2 340 Analog Out 2 388
CntrlNet In 4 326 Logic Options 59 An In 2 Offset 394 An Out 2 Offset 402
CntrlNet In 5 327 An In 2 Scale 395 An Out 2 Scale 403
CntrlNet In 6 328 Analog In 3 341 Analog Out 3 389
CntrlNet In 7 329 An In 3 Offset 396 An Out 3 Offset 404
CntrlNet Out 0 351 An In 3 Scale 397 An Out 3 Scale 405
CntrlNet Out 1 352 Analog In 4 342 Analog Out 4 390
CntrlNet Out 2 353 An In 4 Offset 398 An Out 4 Offset 406
CntrlNet Out 3 354 An In 4 Scale 399 An Out 4 Scale 407
CntrlNet Out 4 355 SP Analog In 338 SP Analog Out 386
CntrlNet Out 5 356 SP Analog Sel 391
CntrlNet Out 6 357
CntrlNet Out 7 358
Drv – Drv
Fault Sel/Sts
SCANport Owners SCANport Masks SCANport I/O
D2D Tsk Interval 9 SP Fault Sts 442 Stop Owner 369 Port Enable Mask 408 Data In A1 314
D2D Baud Rate 10 SP Warn Sts 443 Start Owner 371 Start Mask 410 Data In A2 315
D2D Xmit Addr 11 SP Fault Sel 440 Jog1 Owner 372 Jog Mask 411 Data In B1 316
D2D Xmit Ind 1 14 SP Warn Sel 441 Jog2 Owner 373 Direction Mask 409 Data In B2 317
D2D Xmit Data 1 20 ICN Fault Sel 425 Direction Owner 370 Reference Mask 412 Data In C1 318
D2D Xmit Ind 2 15 ICN Warn Sel 426 Set Ref Owner 374 Local Mask 415 Data In C2 319
D2D Xmit Data 2 21 CP Flt Status 82 Local Owner 375 Clear Fault Mask 413 Data In D1 320
D2D Rcv 1 Addr 12 VP Flt Status 83 Flux Owner 376 Reset Drive Mask 414 Data In D2 321
D2D Rcv 1 Ind 1 16 CP Warn Status 84 Trim Owner 377 Data Out A1 343
D2D Rcv 1 Data 1 22 VP Warn Status 85 Ramp Owner 378 Data Out A2 344
D2D Rcv 1 Ind 2 17 CP Fault Select 86 Clr Fault Owner 379 Data Out B1 345
D2D Rcv 2 Data 2 23 CP Warn Select 87 Data Out B2 346
D2D Rcv 2 Addr 13 VP Fault Select 88 Data Out C1 347
D2D Rcv 2 Ind 1 18 VP Warn Select 89 Data Out C2 348
D2D Rcv 2 Data 1 24 Ncfg Flt Status 81 Data Out D1 349
D2D Rcv 2 Ind 2 19 PwrUp Flt Status 80 Data Out D2 350
D2D Rcv 2 Data 2 25 Max DB Power 77
Max DB Temp 78
DB Time Const 79
Shaded parameters are Standard 1336 FORCE parameters.

Table of Contents

Other manuals for Allen-Bradley 1336 FORCE

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allen-Bradley 1336 FORCE and is the answer not in the manual?

Allen-Bradley 1336 FORCE Specifications

General IconGeneral
BrandAllen-Bradley
Model1336 FORCE
CategoryController
LanguageEnglish

Related product manuals