EasyManuals Logo

Allen-Bradley 1336 FORCE User Manual

Allen-Bradley 1336 FORCE
324 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #208 background imageLoading...
Page #208 background image
Chapter 5
Programming Parameters
5–82
I/O Stop Select 1
[Stop Select 1]
Parameter Number 387
Parameter Type Sink
Display Units x
Drive Units None
Factory Default 0
Minimum Value 0
Maximum Value 3
This parameter selects the stopping mode
for a valid stop command.
3 = Param 59 Bits 4 or 5
2 = Current limit stop
1 = Ramp Stop
0 = Coast Stop
Input Status
[Input Status]
Parameter Number 386
Parameter Type Source
Display Units Bit
Drive Units None
Factory Default 0000 0000
Minimum Value 0000 0000
Maximum Value 1111 1111
Enums:
This parameter displays the on/off status of
inputs 1-8 at TB3.
1 = ON
0 = Off
Bit Condition
0
1
2
Input 1
Input 2
Input 3
Bit Condition
3
4
5
Input 4
Input 5
Input 6
Bit Condition
6
7
Input 7
Input 8
Input Mode
[Input Mode]
Parameter Number 385
Parameter Type Sink
Display Units x
Drive Units None
Factory Default 1
Minimum Value 1
Maximum Value 30
Enums:
This parameter selects the functions of the
inputs 1-9 at TB3.
Mode
1
2
3
4
5, 27
6
7
8
9, 28
10, 29
11
12
13
14
15, 30
16
17
18
19
20
21
22
23
24
25
26
Input 1
Status
Start
Start
Start
Start
Start
Start
Start
Start
Start
Start
Run Fwd
Run Fwd
Run Fwd
Run Fwd
Run Fwd
Start
Start
Start
Start
Start
Start
Run Fwd
Run Fwd
Run Fwd
Run Fwd
Input 2
Stop
Stop
Stop
Stop
Stop
Stop
Stop
Stop
Stop
Stop
Stop
Stop
Stop
Stop
Stop
Stop
Stop
Stop
Stop
Stop
Stop
Stop
Stop
Stop
Stop
Stop
Input 3
Status
Rev/Fwd
Rev/Fwd
Rev/Fwd
Rev/Fwd
Rev/Fwd
Rev
Rev
Pot Up
Rev
1st Acc
Run Rev
Run Rev
Run Rev
Run Rev
Run Rev
Rev/Fwd
Rev/Fwd
Spd/Trq3
Spd/Trq3
Rev
Spd/Trq3
Run Rev
Run Rev
Run Rev
Run Rev
Input 4
Status
Jog
Stop Type
1/2 Acc
Pot Up
Jog
Fwd
Fwd
Pot On
Fwd
2nd Acc
Loc/Rem
Stop Type
1/2 Acc
Pot up
Loc/Rem
Proc Trim
Flux En
Spd/Trq2
Spd/Trq2
Fwd
Spd/Trq2
Proc Trim
Flux En
Proc Trim
Jog
Input 5
Status
Ext Fault
Ext Fault
Ext Fault
Ext Fault
Ext Fault
Ext Fault
Ext Fault
Ext Fault
Ext Fault
Ext Fault
Ext Fault
Ext Fault
Ext Fault
Ext Fault
Ext Fault
Ext Fault
Ext Fault
Ext Fault
Ext Fault
Ext Fault
Ext Fault
Ext Fault
Ext Fault
Ext Fault
Ext Fault
Input 6
Status
Spd 3
Spd 3
1/2 Dec
Pot Dn
Loc/Rem
Jog
Spd 3
Spd 3
Pot Up
1st Dec
Spd 3
Spd 3
1/2 Dec
Pot Dn
Stop Type
Ramp
Reset
Spd/Trq1
Spd/Trq2
Ramp
Spd/Trq1
Reset
Reset
Ramp
Spd 3
Input 7
Status
Spd 2
Spd 2
Spd 2
Spd 2
Spd 2
Spd 2
Spd 2
Spd 2
Pot Dn
2nd Dec
Spd 2
Spd 2
Spd 2
Spd 2
Spd 2
Spd 2
Spd 2
Proc Trim
Flux En
Reset
Spd 2
Spd 2
Spd 2
Spd 2
Spd 2
Input 8
Status
Spd 1
Spd 1
Spd 1
Spd 1
Spd 1
Spd 1
Spd 1
Spd 1
Spd 1
Spd 1
Spd 1
Spd 1
Spd 1
Spd 1
Spd 1
Spd 1
Spd 1
Spd 1
Spd 1
Spd 1
Spd 1
Spd 1
Spd 1
Spd 1
Spd 1

Table of Contents

Other manuals for Allen-Bradley 1336 FORCE

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allen-Bradley 1336 FORCE and is the answer not in the manual?

Allen-Bradley 1336 FORCE Specifications

General IconGeneral
BrandAllen-Bradley
Model1336 FORCE
CategoryController
LanguageEnglish

Related product manuals