Chapter 5
Programming Parameters
5–85
Fault Status
[SA Fault Status]
Parameter Number 407
Parameter Type Source
Display Units Bits
Drive Units None
Factory Default 0000 0000 0000 0000
Minimum Value 0000 0000 0000 0000
Maximum Value 1110 0001 0111 1111
Enums:
This parameter displays the fault status of
the SCANport device.
1 = Fault
0 = No Fault
Bit 0 – Not Used
Bit 1 – SCANport Device 1
Bit 2 – SCANport Device 2
Bit 3 – SCANport Device 3
Bit 4 – SCANport Device 4
Bit 5 – SCANport Device 5
Bit 6 – SCANport Device 6
Bit 7 – Not Used
Bit 8 – 4 – 20 mA Loss
Bit 9 – Not Used
Bit 10 – Not Used
Bit 11 – Not Used
Bit 12 – Not Used
Bit 13 – Illegal Drive Type (Not Configurable)
Bit 14 – Diff Drive Type (Not Configurable)
Bit 15 – SCANport error (Not configurable)
Warning Status
[SA Warn Status]
This parameter displays the warning status
of the SCANport device timeouts.
1 = Warning
0 = No Warning
Bit 0 – Not Used
Bit 1 – SCANport Device 1
Bit 2 – SCANport Device 2
Bit 3 – SCANport Device 3
Bit 4 – SCANport Device 4
Bit 5 – SCANport Device 5
Bit 6 – SCANport Device 6
Parameter Number 408
Parameter Type Source
Display Units Bits
Drive Units None
Factory Default 0000 0000 0000 0000
Minimum Value 0000 0000 0000 0000
Maximum Value 0000 0001 0111 1111
Enums:
Bit 8 – 4–20 mA Loss
Bit 9–15 – Not Used
Fault Select
[SA Fault Select]
Parameter Number 405
Parameter Type Sink
Display Units Bits
Drive Units None
Factory Default 0000 0000 0111 1111
Minimum Value 0000 0000 0000 0000
Maximum Value 0000 0001 0111 1111
Enums:
This parameter chooses whether a SCAN-
port device causes a drive fault, a warning
based on ‘SA Warn Sel’ (P406) or does
nothing.
1 = Fault
0 = Warning/Nothing
Bit 5 – SCANport Device 5
Bit 6 – SCANport Device 6
Bit 7 – Not Used
Bit 8 – 4–20 mA Loss
Bit 9–15 – Not Used
Warning Select
[SA Warn Select]
Parameter Number 406
Parameter Type Sink
Display Units Bits
Drive Units None
Factory Default 0000 0000 0111 1111
Minimum Value 0000 0000 0000 0000
Maximum Value 0000 0001 0111 1111
Enums:
This parameter selects whether a SCAN-
port device timeout causes a warning or
does nothing.
1 = Warning
0 = Does Nothing
Bit 0 – Not Used
Bit 1 – SCANport Device 1
Bit 2 – SCANport Device 2
Bit 3 – SCANport Device 3
Bit 4 – SCANport Device 4
Bit 5 – SCANport Device 5
Bit 6 – SCANport Device 6
Bit 7 – Not Used
Bit 8 – 4–20 mA Loss
Bit 9–15 – Not Used
Bit 0 – Not Used
Bit 1 – SCANport Device 1
Bit 2 – SCANport Device 2
Bit 3 – SCANport Device 3
Bit 4 – SCANport Device 4

Table of Contents

Other manuals for Allen-Bradley 1336 FORCE

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allen-Bradley 1336 FORCE and is the answer not in the manual?

Allen-Bradley 1336 FORCE Specifications

General IconGeneral
BrandAllen-Bradley
Model1336 FORCE
CategoryController
LanguageEnglish

Related product manuals