388 Rockwell Automation Publication 1444-UM001D-EN-P - June 2018
Appendix A CIP Objects
*A latched alarm buffer requires a reset to rearm it ready for a new trigger/
alarm event. (Status is set to armed, zero stored records that are indicated and
earlier data is no longer available.) The reset service (or via the controller
output data) sends an alarm buffer reset.
If an alarm buffer reset is sent, the buffer will resets/rearms as described,
irrespective of whether latching is configured. This reset acts as a marker that
the data has been read/is finished with. The reset also provides for a clear
indication of when a new event has been detected.
22 Order (1)Mag
Channel 2
FFT Band (10) SMAX Phase Channel Pair 0
23 Order (1)Mag
Channel 3
FFT Band (11) SMAX Phase Channel Pair 1
24 Order (1)
Phase Channel 0
FFT Band (12) Shaft Absolute
pk-pk Channel Pair 0
25 Order (1)
Phase Channel 1
FFT Band (13) Shaft Absolute
pk-pk Channel Pair 1
26 Order (1)
Phase Channel 2
FFT Band (14) Speed 0
27 Order (1)
Phase Channel 3
FFT Band (15) Speed 1
28 Order (2)Mag
Channel 0
FFT Band (16) Speed 0 maximum
29 Order (2)Mag
Channel 1
FFT Band (17) Speed 1 maximum
30 Order (2)Mag
Channel 2
FFT Band (18) Speed 0 Rate of Change
21 Order (2)Mag
Channel 3
FFT Band (19) Speed 1 Rate of Change
Table 115 - Static Data Bit Allocations (continued)
Bits DWORD 0 DWORD 1 DWORD 2 DWORD 3
Table 116 - Common Services
Service
Code
Implementation Service Name Description of Service
Class Instance
0x05 x x Reset* Alarm buffer reset
0x0E x x Get Attribute Single Returns the contents of the specified attribute