Publication 1756-RM084F-EN-P - July 2002
Creating a Complete Import/Export File 3-15
RemoteElement
Specify the address or tag name of the element in the remote device. This is the source
element of a read instruction or the destination element of a write instruction.
Specify:
RemoteElement :=
text
RequestedLength
Specify the number of elements to be transferred (0-32,767).
Specify:
RequestedLength :=
value
ConnectedFlag
Specify whether the CIP generic message requires a connection or not. Enter 1 for
connected; enter 0 for not connected.
Specify:
ConnectedFlag :=
value
ConnectionPath
Specify the connection path to the other device.
Specify:
ConnectionPath :=
string
CommTypeCode
Specify the type of communication method.
Enter For this communication method
0 CIP (most messages use CIP communications)
1 DH+
2 CIP with source ID
3 block transfer via universal remote I/O
4 block transfer via ControlNet
Specify:
CommTypeCode :=
value
Channel
For a DH+ or block transfer message, specify the channel. Enter either A or B.
Specify:
Channel :=
value
Rack
For a DH+ or block transfer message, enter the rack number (0-77 octal) of the
target device.
Specify:
Rack :=
value
Group
For a DH+ or block transfer message, enter the group number (0-7) of the target device.
Specify:
Group :=
value
Slot
For a DH+ or block transfer message, enter the slot number (0-15) of the target device.
Specify:
Slot :=
value
LocalIndex
Specify the index into the local element, typically 0.
Specify:
LocalIndex :=
value
RemoteIndex
Specify the index into the remote element, typically 0.
Specify:
RemoteIndex :=
value
LocalElement
Specify the tag name of the element in the local controller. This is the destination element
of a read instruction or the source element of a write instruction.
Specify:
LocalElement :=
text
DestinationTag
Specify the tag name of the destination element.
Specify:
DestinationTag :=
text
SourceLink
If the communication method uses DH+, specify the source link (0-199).
Specify:
DHPlusSourceLink :=
value
DestinationLink
If the communication method uses DH+, specify the destination link (0-199).
Specify:
DHPlusDestinationLink :=
value
DestinationNode
If the communication method uses DH+, specify the destination node number (0-77 octal).
Specify:
DHPlusDestinationNode :=
value
ServiceCode
If the message type is CIP Generic, specify the service code (0-32,767 hexadecimal).
Specify:
ServiceCode := 16#
value
Attribute: Description: