Chapter 6 Configure and Start the Kinetix 5700 Drive System
Fault Log
Fault text Fault code as listed in Fault Codes
on page 277. FLT S20 - CONV OVERLOAD FL
Fault details The problem as reported in Fault Codes
on page277
The converter thermal model indicates that the
temperature has exceeded the factory set capacity rating
of 110%.
Fault help The Possible Solution as reported in Fault Codes
on page 277.
• Reduce the number of drives in the same bus group
• Reduce duty-cycle of commanded motion
Table 102 - Navigating the DC-bus Power Supply Menu
Menu/Sub Menu
Selections
Attributes Description Example Values
Module Info
Catalog number 2198-Pxxx
Firmware revision FW REV: 1.1.450167
Hardware revision HW REV: 1.1
Serial number SERIAL#: xxxxxxxxxxx
Diagnostics>
Converter
Diagnostics
Bus diagnostics
BUS VOLT: 0.0V
BUS CUR: 0.0A
Converter diagnostics
CONV UTIL: 0.7%
CONV TEMP: 31.7C
Shunt utilization SHUNT UTIL: 0.0%
Fault Log
Fault text Fault code as listed in Fault Codes
on page 277. FLT S18 - CONV OVERTEMP FL
Fault details The problem as reported in Fault Codes
on page277
The measured converter temperature has exceeded the
factory set temperature limit.
Fault help The Possible Solution as reported in Fault Codes
on page 277. Reduce the number of drives in the same bus group.