Rockwell Automation Publication 2094-UM002G-EN-P - August 2016 31
Plan the Kinetix 6200 and Kinetix 6500 Drive System Installation Chapter 2
Input Power Circuit Protection (without LIM)
The fuses and Allen-Bradley circuit breakers shown in Tabl e 8 are recommended for use with 2094-BCxx-Mxx-M IAM
power modules when the line interface module (LIM) is not used.
Table 8 - Input Power Circuit Protection Specifications
Refer to the Kinetix Servo Drives Technical Data, publication KNX-TD003, for additional power specifications for your
IAM power module.
IMPORTANT LIM Module (catalog number 2094-BLxxS) provides branch circuit protection to the IAM power module. Follow all applicable
NEC and local codes.
Kinetix 6200 and Kinetix 6500
Drives
UL Applications IEC (non-UL) Applications
IAM Module
Cat. No.
Drive Voltage
(three-phase)
nom
Fuses (Bussmann)
Cat. No.
Miniature CB
Cat. No.
Motor Protection CB,
Self-protected CMC
Cat. No.
Molded Case CB
Cat. No.
Miniature CB
Cat. No.
Motor Protection CB
Cat. No.
Molded Case CB
Cat. No.
2094-BC01-MP5-S 360…480V
KTK-R-20 (20 A)
Class CC
1489-M3D300
140M-F8E-C32
NA
1492-SPM3D300 1489-M3D300
140M-F8E-C32
NA2094-BC01-M01-S 360…480V
KTK-R-20 (20 A)
Class CC
140M-F8E-C32 140M-F8E-C32
2094-BC02-M02-S 360…480V
KTK-R-30 (30 A)
Class CC
1489-M3D400 140M-F8E-C45 1492-SPM3D400 1489-M3D400 140M-F8E-C45
2094-BC04-M03-S 360…480V
LPJ-45SP (45 A)
Class J
N/A NA
140G-G6C3-C50
N/A N/A NA
140G-G6C3-C50
2094-BC07-M05-S 360…480V
LPJ-80SP (80 A)
Class J
140G-G6C3-C90 140G-G6C3-C90