EasyManua.ls Logo

Allen-Bradley Kinetix 6200 - Page 81

Allen-Bradley Kinetix 6200
336 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Rockwell Automation Publication 2094-UM002G-EN-P - August 2016 81
Connector Data and Feature Descriptions Chapter 4
Table 40 - Stegmann Hiperface Specifications
Figure 41 - Stegmann Hiperface Interface, MTR_SIN and MTR_COS Signals
Figure 42 - Stegmann Hiperface Interface, MTR_DATA Signals
Attribute Value
Protocol Hiperface
Memory support Not programmed, or programmed with Allen-Bradley motor data
Hiperface data communication 9600 baud, 8 data bits, no parity
Sine/cosine interpolation 2048 counts/sine period
Input frequency (AM/BM) 250 kHz, max
Input voltage (AM/BM) 0.6...1.2V, p-p, measured at the drive inputs
Line loss detection (AM/BM) Average (sin
2
+ cos
2
) > constant
Noise filtering (AM and BM) Two-stage coarse count pulse reject filter with rejected pulse tally
Incremental position verification
Position compare between incremental accumulator and serial data
performed every 50 ms or less
56 pF
MTR_SIN+ or
MTR_COS+
MTR_SIN- or
MTR_COS-
+
1 k
Ω
+
to AqB Counter
1 k
Ω
1 k
Ω
1 k
Ω
121
Ω
56 pF
220 pF
2 k
Ω
220 pF
to A/D Converter
2 k
Ω
+2.5V
+2.5V
-
-
Kinetix 6200 or Kinetix 6500
Control Module
+
to UART
from UART
from UART
100 pF
MTR_DATA+
MTR_DATA-
1 k
Ω
to AqB Counter
1 k
Ω
1 k
Ω
100 pF
1 k
Ω
121
Ω
56 pF
56 pF
+5V
-
Shaded area indicates components that are part of the circuit, but support
other feedback device types (not used for Stegmann Hiperface support).
Kinetix 6200 or Kinetix 6500
Control Module