Specifications
51Alvium G1 User Guide V1.7.0
IEC 60068-2-27: Shock
IEC 60068-2-64: Random vibration
Parameter Value
Axis x, y, z
Acceleration 20 g
Number of shocks per axis 10
Duration per axis 11 ms
Waveform Half sine
Table 13: Parameters for IEC 60068-2-27 tests
Frequency Acceleration
15 Hz to 500 Hz
0.05 g
2
/
Hz
Table 14: Frequency and acceleration for IEC 60068-2-64 tests
Parameter Value
Axis x, y, z
Acceleration RMS (Sigma) 4.9 g
Acceleration peak (Sigma) 14.8 g
Duration per axis [hh:mm:ss] 00:30:00
Table 15: Other parameters for IEC 60068-2-64 tests