Vipros 357 Queen with Fanuc 18PC User Pre-installation Guide ©Amada America, Inc.
Print Date 01/24/2001 Revision 4.0 This document available on the World Wide Web at http://www.amada.com Page 10 of 37
Supply Requirements - Electrical
Vipros 357 Queen 230 / 460 / 3 / 60 ±10%, 30 kVA
76 amps @ 230 / 3 / 60 VAC*
38 amps @ 460 / 3 / 60 VAC*
SBC EX 5.5 Chiller
Chiller voltage must be specified when
machine is ordered.
230 or 460 / 3 / 60 ±10%, 15 kVA
38 amps @ 230 / 3 / 60 VAC*
19 amps @ 460 / 3 / 60 VAC*
Optional Equipment
V357hs Conveyor 208 / 230 / 460 3ph ±10%, kVA
2.1 amps @ 208 / 3/ 60 VAC*
2.0 amps @ 230 / 3 / 60 VAC*
1.0 amps @ 460 / 3 / 60 VAC*
MP1225 Loader 200 / 3 / 60 ±10%, 10 Kva
29 amps @ 200 / 3 / 60 VAC*
To operate at 230 / 460 VAC a step up transformer with the following
service is required
26 amps @ 230 / 3 / 60 VAC*
13 amps @ 460 / 3 / 60 VAC*
* The actual supplied electrical service must be sized to allow for starting current of approximately 150% of this value.