Commissioning
Amatron+ BAG0063.1 03.10 39
5.6.1 Taring/calibrating weighing cell
The weighing cell is tared and calibrated at the
factory. However, if there are differences be-
tween the actual and the spread quantity or the
hopper contents, the weighing cell needs to be
recalibrated.
See Service Set-up
, Basic data menu,
page one
.
The weighing cell should be tared if
special equipment is fitted
Fig. 49
1. Empty the fertiliser spreader completely (enter Machine data,
page one
,
page 19), and wait until the symbol
goes out.
2.
Confirm.
3. Park the tractor and attached spreader on a horizontal surface
and wait until the
symbol goes out.
CAUTION
If the symbol appears in the display, the tractor is still mov-
ing.
4.
Press
→ The spreader is tared.
5. Load a precisely weighed, minimum 500 kg of fertiliser and wait
until the
symbol goes out.
6
.
Confirm.
7. Enter the weighted amount of fertiliser in kg in the kg
AMATRON
+
→ The spreader is calibrated.
Check by comparing the display in the work menu with the quantity of
fertiliser added.