Malfunction
70 Amatron+ BAG0063.1 03.10
9.3 Failure of setting motors
If faults occur in the AMATRON
+
or electric
setting motors and cannot be rectified immedi-
ately, you can still continue working:
after extending the setting motors,
after modifying the setting lever.
The rate as per setting chart is then determined
by means of the setting lever (Fig. 81/1).
1. Clos
e the hydraulic slider.
2. Release the thumb screw (Fig. 81/2).
3. Look for the required sli
der position on the
scale (Fig. 81/3).
4. Adjust the read-off edg
e (Fig. 81/4) of the
setting lever pointer (Fig. 81/5) so that it
correspond
s to the scale value.
5. Insert washers behind the setting lever.
6. Retighten the thumb screw (Fig. 81/2).
Fig. 81
Fig. 82
Extending the setting motors and modifying the setting lever:
1. Remove the two securing clips (Fig. 82/3) with pliers /.
2. Withdraw the two hing
e pins (Fig. 82/4).
3.
Remove the
setting moto
r (Fig. 82/1) from the console.
4. Rais
e the setting motor /and detach the pushrod (Fig. 82/2) from
the plug-i
n co
nne
ction of the dosi
ng slider.
5. Then again secure the setting motor with detached pushrod in
the engine console in accordance with regulations.