Use on the field
60 Amatron+ BAG0063.1 03.10
6.7 Emptying fertiliser hopper
The remaining fertiliser in the hopper can be
emptied via the hopper tips.
1. Remove the spreader discs (see machine
operating manual)
2. Machine data menu:
, Open both dosing sliders.
3. Open both slide gates.
Operate tractor controllers 1 and 2.
ZA-M Hydro, Comfort:
Remaining fertiliser runs out.
Stow the machine with the sliders opened.
Close the sliders before refilling.
Fig. 69
WARNING
Risk of injury near the rotating agitators and spreading disc
drive.
Make sure the agitators and disc drive are s witched off when empty-
ing the residue.