Maintenance and cleaning
Amatron+ BAG0063.1 03.10 63
8 Maintenance and cleaning
WARNING
Perform maintenance and cleaning only with the spreader discs
and agitator shaft drive switched off.
8.1 Cleaning
DANGER
Do not reach into the outlet opening while operating the sliders!
Risk of crushing!
To clean the fertiliser spreader, you must have the slide gates and the
electric dosing sliders open so the water and residual fertiliser can
drain.
Opening/closing dosing sliders (see Machine data menu, page
19).
Opening/closing slide gates (see ZA-M Hydro / ZA-M
Comfort work menu).
8.2 Basic slide setting
The amount of cross-sectional clearance of the
electric dosing sliders is set at the factory (Fig.
73).
If, despite identical slider positions, you find that
the two hopper tips are not emptying uniformly,
check the basic setting of the sliders.
Fig. 73
Specify the basic setting for both rate slides us-
ing the Set-up menu:
1.
Select basic data.
Page two (Fig. 74)
2.
Set left slider position.
3.
Set right slider position.