152 ARX 23-2 T4i, ARX 26-2 T4i
593059
593059
593047
1
3.6 Lubrication and maintenance operations
Hydraulic circuit lling
Take out the ventilation lter.
Fill the hydraulic oil through the hole into the tank.
Replace the ventilation lter with anew one.
Lubricate the seal ring of the new lter cap with oil.
Mount anew lter (1).
Carry out the oil change when the oil is warm, preferably
after operation of the machine.
Let the drained oil cool down below 50°C (122 °F).
Rell the same type of oil.
Stop the oil soaking into the ground.