8 Maintenance
BNNbOO
ID: 1138310 Issue date January 01, 2010
116
Checks – Seat contact and emergency stop
Move the drive lever (1) to zero
position.
Sit on the driver's seat and start the
engine.
The control lamp for emergency stop
circuit, operating lever neutral position
and seat switch (1) must extinguish
immediately.
Leave the seat.
After 0.7 seconds the control lamp for
the emergency stop circuit, operating
lever neutral position and seat contact
(1) light up.
Switch off the engine.
NOTE
The control lamp for the emergency stop circuit, operating lever neutral
position and seat contact must extinguish after 2 seconds for delayed seat
contact.