- 28 -
Advanced Programming
1. Fertilization Supplement (F)
In the fertilization selection mode the times for fertilization are set for each individual valve.
It is possible to add fertilization prior to irrigation starting times from 10% to 90% of the specic valve
duration time. Fertilization will always be given during the valve irrigation .
Example: A specic valve has been programmed for the duration of 60 minutes. Fertilization
supplement is set for 20%. Regular irrigation will be operated for the rst 24 minutes (without
fertilization). Subsequently fertilization will be added for the next 12 minutes (20% of the scheduled
time); following fertilization regular irrigation will continue for the next 24 minutes, so the line can be
washed.
• Turn selector to Fertilization mode. Symbol of the fertilization valve (F) and % symbol will appear
on display panel.
• Press on
until the valve you wish to select for your fertilization % supplement blinks on and off.
• 00 will appear on display panel. Press on
. 00 will blink. Set the percentage time as desired by
using the
and buttons as necessary.
• Repeat the above steps for any other valve needed.
The selector should be returned to the TIME/DAY mode
following modification or ending of the program.