- 32 -
5. Suspension- Rain Off
This option is used to temporarily suspend the irrigation controller's control of a number or all of the
valves, for example, when it is raining. The irrigation schedule remains stored in the controller but is
not implemented.
In the ALL mode, suspension will disable all of the valves. According to the designation of
valve-groups (in Programs A, B, C or I), some rather than all valves may be disabled.
Suspension may be operated from one day and up to 99 days. At the end of the suspended time, the
controller will return to its original schedule as previously programmed.
1. Suspension of All Valves
•Turn selector to Suspension mode.
, DAYS 0, the word ALL and valve symbols will appear on
display panel.
• Press on
. DAYS 0 will begin to blink. Set the number of suspension days necessary for all of the
valves using
and .
2. Suspension of Valves Attributed to Programs A, B, C or I
• Press on
until Program A and Symbol of Valves attributed to Program A will appear on display
panel.
• Press on
. DAYS 0 will begin to blink. Set the number of suspension days necessary for all
valves attributed to Program using the
and .
Note! If valves attributed to one of the programs has already been programmed for
suspension, it is not possible to suspend all valves in ALL mode.
Advanced Programming
The selector should be returned to the TIME/DAY mode
following modication or ending of the program.