CHAPTER 4
OPERATING INSTRUCTIONS
Entire Contents Copyright 2004 by Adaptive Power Systems, Inc. (APSI) • All Rights Reserved • No reproduction without written authorization from APSI.
APS-3000P Series 4 - 5 OM-001-03000-00P-03.9
Current Limit Setting
When the system is in RESET (Standby) or TEST (Output ON) mode, press the
CURRENT ︿ or ﹀ buttons to display the preset Current Limit value.
Press the ︿ or ﹀ buttons again to adjust the value. When unchanged for two seconds,
the current limit adjustment terminates and the system returns to the previous setting
interface. When the current limit value is OFF, the system will protect itself by limiting
the current according to output capacity (see Specifications).
Note: If your unit shuts down due to a detected Over-Current condition, the
FREQUENCY display shows OCP.
C U R R E N T
LOCK
REMOTE
AUTO
MANUAL
PROGRAM SYSTEM