SPA BEHAVIOR
34
minute every 30 minutes to detect the spa temperature (polling) and then
to heat to the set temperature if needed. When the low-speed turns on
automatically, it cannot be deactivated from the panel, however the high
speed may be started.
CIRCULATION PUMP MODES
If the system is equipped with a circ pump, it will be congured to work in
one of three different ways:
1, The circ pump operates continuously (24 hours) with the exception of
turning off for 30 minutes at a time when the water temperature reaches
3°F (1.5°C) above the set temperature (most likely to happen in very hot
climates).
2, The circ pump stays on continuously, regardless of water temperature.
3, A programmable circ pump will come on when the system is check-
ing temperature (polling), during lter cycles, during freeze conditions, or
when another pump is on. The specic Circulation Mode that is used has
been determined by the Manufacturer and cannot be changed in the eld.
Other device options may be available, like Blower, Light, Mister, etc.
FILTRATION AND OZONE
On non-circ systems, Pump 1 low and the ozone generator will run during
ltration. On circ systems, the ozone will generally run with the circ pump,
but can be limited to ltration cycles. (On some circs systems, Pump 1 low
will run along with the circ Pump during ltration.)
The system is factory-programmed with one lter cycle that will run in the
evening (assuming the time-of-day is properly set) when energy rates are
often lower. The lter time and duration are programmable.
A second lter cycle can be enabled as needed.
At the start of each lter cycle, the water devices like blower, mister device
(if these exist) and other pumps will run briey to purge the plumbing to
maintain good water quality.