THE WATER IS TOO HOT – M029
The system has detected a spa water temp of 110°F (43.3°C) or more,
and spa functions are disabled. System will auto reset when the spa water
temp is below 108°F (42.2°C). Check for extended pump operation or
high ambient temp.
THE WATER LEVEL IS TOO LOW
This message can only appear on a system that uses a water level sensor.
It appears whenever the water level get too low
(or the water level sensor is disconnected), and automatically disappears
when the water level is adequate. Pumps and the
heater turn OFF when this message appears.
HEATER RELATED MESSAGES
THE WATER FLOW IS LOW – M016
There may not be enough water ow through the heater to carry the heat
away from the heating element. Heater start up will begin again after about
1 min.
THE WATER FLOW HAS FAILED – M017
There is not enough water ow through the heater to carry the heat away
from the heating element and the heater has been disabled. After the
problem has been resolved, reset the message*.
THE HEATER MAY BE DRY – M028
Possible dry heater, or not enough water in the heater to start it. The spa
is shut down for 15 min. Reset this message* to reset the heater start-up.
THE HEATER IS DRY* – M027
There is not enough water in the heater to start it. The spa is shut down.
After the problem has been resolved, you must reset the message* to
restart heater start up.