UTILITIES - GFCI TEST FEATURE
WARNING:
On those systems that automatically test the GFCI within 1 to 7 days after
startup: The end-user must be trained to expect this one-time test to occur.
The end-user must be trained how to properly reset the GFCI.
If freezing conditions exist, the GFCI or RCD should be reset immediately
or spa damage could result.
CE PRODUCT
CE registered systems do not have an RCD Test Feature due to the nature
of the electrical service.
Some UL registered systems do not have the GFCI Test Feature activated.
The end-user must be trained how to properly test and reset the RCD.
RESET BUTTON:
Only use the Reset Button prior to moving the spa to a new location.
Pressing the Reset the button forces a new Test to be performed at the
new location.
GENERAL MESSAGES
Most messages and alerts will appear at the bottom of the normally used
screens. Several alerts and messages may be displayed in a sequence.
– – – –°F – – – –°C
WATER TEMPERATURE IS UNKNOWN
After the pump has been running for 1 minute, the temperature will be
displayed
POSSIBLE FREEZING CONDITION
A potential freeze condition has been
detected, or the Aux Freeze Switch
has closed. All water devices are
activated.
In some cases, pumps may turn on
and off and the heater may operate
during Freeze Protection.
This is an operational message,
not an error indication.
47
Warning
Message Code: 1
Possible Freezing Condition