5. Handset Configuration
Configure Presence settings group (sub group)
1 Select System Profiles > System Profiles Sub Groups > Presence groups > Presence
group X.
2In the Message absence drop-down list, select one of the following:
• On - When a handset receives a message, it indicates it is absent. The message
can be redirected to another destination and is system dependent.
• Off - The message absence is disabled.
3In the Name of group field, enter a descriptive name.
Configure Alarm Settings Group (sub group)
1 Select System Profiles > System Profiles Sub Groups > Alarm settings group > Alarm
settings X.
2In the Name of group field, enter a descriptive name.
3 Select System Profiles > System Profiles Sub Groups > Alarm settings group > Alarm
settings X > Common.
• Stored alarm data - Information that is sent with an alarm (for example a
handset´s location)
• Indicate triggered alarm with LED
1
• Indicate triggered alarm with vibrator
1
• Indicate triggered alarm with beeper signal
1
4 Select System Profiles > System Profiles Sub Groups > Alarm settings group > Alarm
settings X > Alarm on long press
• Alarm type for long press - Determines the alarm type to be sent when long
pressing the alarm button. If Not used is selected, the call can still be dialled after
alarm number (if any, see
5.26 Common Alarm Settings on page 37) without
sending an alarm.
• ALS - Determines if a ramped up signal sounds after an alarm is sent. Note: If the
handset is configured to call a predefined number when an alarm is sent (see
5.26
Common Alarm Settings on page 37), the ALS is not triggered.
5 Select System Profiles > System Profiles Sub Groups > Alarm settings group > Alarm
settings X > Alarm on multiple press
• Alarm type for multiple press - Determines the alarm type to be sent when
pressing the alarm button twice or more. If Not used is selected, it is still possible
to dial the call after alarm number (if any, see
5.26 Common Alarm Settings on
page 37) without sending an alarm.
• ALS - Determines if a ramped up signal sounds after an alarm is sent. Note: If the
handset is configured to call a predefined number when an alarm is sent (see
5.26
Common Alarm Settings on page 37), the ALS is not triggered.
1. If the parameter "Silent alarm" is set, no indication is shown when an alarm has been sent or received.