ADR141A /
1A
Doc ID : ADR241A_IM_01
Ref ID : ADR241A/IM/I&S
Rev No. : 02
Page No. : 27 of 150
CE compliance
I. Immunity : IEC-60255-26
II. Emissive Test : IEC- 60255-26
III. Low voltage directive : EN-50178
Mechanical tests
I.
Vibration
Endurance Test
: IEC 60255-21-1 class 2
: Frequency Range = 10Hz – 250Hz, acceleration. = 2gn
: Sweep rate 1 octave/min; 20 cycle in 3 orthogonal axis.
II.
Vibration
Response Test
: IEC 60255-21-1 class 2
: Frequency Range = 10Hz – 150Hz , acceleration. = 1gn
: Sweep rate 1 octave/min; Displacement =0.075mm, in 3
orthogonal axis.
III.
Bump Test : IEC 60255-21-2 Class-1
: 1000 bumps / direction of 10gn peak acceleration and 16ms pulse
duration in each of the two opposite direction per axis as per No. of
axes. 3.
IV.
Shock Withstand
Test
: IEC 60255-21-2 Class-2 30g, 11ms
: 3 shocks of 15gn peak acceleration and 11ms pulse in each of
two opposite direction. No. of axis : 3
V.
Shock Response
Test
: IEC 60255-21-2 Class-2
: 5 shocks of 10gn peak acceleration and 11ms pulse in each of
two opposite direction. No. of axis : 3
VI.
Seismic Test : IEC 60255-21-3 Class-2
: Sweep 1/Axis (@a sweep rate of 1 octave/minute) vibration in the
frequency range (5-35 Hz) at displacement X-axis: 7.5mm, Y-axis:
3.5mm amplitude of 3.5mm with acceleration of X-axis: 2gn, Y-axis:
1gn.