Conguring the Unit via its Web Interface
System
ENC 1201 Version 1.0 Page 24
Password
By default, the ENC 1201’s password is “password”. To avoid tampering by unauthorized
users, we recommend specifying a dierent password. Be sure to write it down some-
where in case you forget it.
In scenarios where speed is of the essence, you may want to skip the password stage for
logging into the unit. In that case, delete all dots from the “Password” eld. This clears the
password. As a result, the [Login] (and [Logout]) button is no longer displayed in the Func-
tion bar, and you will be automatically logged in.
Note:
• If you forgot the password, you can reset the ENC 1201 using Dante Controller: double-click the
ENC 1201’s name in the “Network View” window (to open the “Device View”), click [Device Con-
g] and [Clear Cong] to reset the ENC 1201. You also need to reboot it. Note that resetting the
ENC 1201 causes it to load the factory default settings.
PersistDanteSettings
Set “Persist Dante Settings” to “OFF” if you want the ENC 1201 to automatically save edits
made via Dante (using Dante Controller, for instance). Such changes will overwrite the
internal conguration and are recalled when you reboot the unit.
Select “ON” if the ENC 1201 should only use changes made from a remote location until it
is rebooted. At that time, the settings of the internal conguration are recalled.
PowerSupply1/PowerSupply2
“Power Supply 1” and “Power Supply 2” display the current status of the two power sup-
plies:
OK The status is OK—this power supply powers the ENC 1201.
FAULT This power supply is either not connected to a wall outlet or faulty.