5200 Series Programming Instructions
17
80-9352-0022-020 Rev 2 06/23
Copyright © 2023, ASSA ABLOY Accessories and Door Controls Group, Inc. All rights reserved. Reproduction in whole or in
part without the express written permission of ASSA ABLOY Accessories and Door Controls Group, Inc. is prohibited.
Wave to Open Wiring Diagram
P
ower +
N/C
C
N/O
P
ower–
1 Sec
5 Sec 10 Sec 15 Sec 20 Sec 25 Sec 30 Sec 35 Sec
LED Setting:
Time Delay Setting:
Jumper in place:
LED is Red and
flashes Green when
relay is active.
No Jumper:
LED is Green and
flashes Red when
relay is active.
Wave to Open Switch Detail