Syn248 Installation and Configuration Guide Back to Contents
Installation 15
Gateway Placement
You can install the Gateway in a standard 19-inch rack, on a desktop, or mount it on a
wall. The Gateway must be installed within three feet of the building ground point. Install
each device using the following instructions.
Rack Mounting
To mount the Gateway into a standard 19-inch rack:
1. Remove the two mounting brackets and six screws from the packing tissue.
2. Position a bracket at the front of the device and align the screw holes using the
locating indentation.
3. Insert each of the three screws into the holes provided and tighten securely. Repeat
the process for the other bracket.
4. Position the chassis into the rack.
5. Insert a top mounting screw (not included) in one side and turn it several turns to
establish support. Repeat for the other side.
6. Tighten the screws.
Locating Indentation