15
Operator's instructions  
1. General 
 
The emergency stop buttons/cables are connected in series with the diesel engine cut- 
out system. As soon as an emergency stop button/cable is activated, the diesel engine 
will be stopped immediately. Reset the emergency stop buttons before restarting the  
engine. The engine cannot be started while one of the emergency stops is still acti- 
vated.  
 
For further details, see separate wiring diagram.  
 
For details of the diesel engine, see separate diesel engine instructions.  
 
 
Hydraulic system  
The principal components of the hydraulic system comprise oil cooler, hydraulic oil  
tank, valves, hoses and four hydraulic pumps.  
 
The four hydraulic pumps create hydraulic pressure in order to control the different 
functions. The table below indicates which hydraulic pump controls which function. 
 
 
Table: Description of hydraulic pump function 
 
 
Pump No. 
Description 
1  All movements and percussion 
2 Carriage translation 
3 DCT, cooling fan 
 
The hydraulic oil tank is located in the centre of the drilling carriage.  
 
The radiator on the right side of the drilling carriage cools the water of the engine, 
the intercooler and the oil compressor. The radiator on the left side cools the 
hydraulic oil.