9.
Affix the above sheet explaining the procedure for checking the motor rotation direction to the cooling
air outlet of the compressor.
Check the rotation direction of the motor using the sheet. If the motor rotation direction is correct, the
sheet on the top grating will be blown upwards. If the sheet remains in place, the rotation direction is
incorrect (see the pictographs on the label).
If the rotation direction is incorrect, switch off the voltage, open the isolating switch and reverse two
incoming supply lines.
10. Check the programmed settings. Consult section Programmable settings.
11. Start and run the compressor for a few minutes. Check that the compressor operates normally.
7.2 Before starting
Procedure
- Check the oil level, top up if necessary. See section Initial start-up.