Type V Approval Overload Relay
Pack
Overload Relay
Full Feature
MAX Setting (A) MAX Setting (A)
GA 11 400 + N IEC 32 30 40 37
GA 11 460 IEC 32 26 32 30
GA 11 500 IEC 25 24 32 27
Type V Approval Overload
setting (FM1)
(A)
Fuse rating (A)
Class J or RK
Pack Full Feature
GA 5 200 CSA/UL 34.5 40 45
GA 5 200/230/460 CSA/UL 33/30/15 40/40/20 40/40/20
GA 5 575 CSA/UL 12 15 20
GA 7 200 CSA/UL 44.5 50 60
GA 7 200/230/460 CSA/UL 43/39/19 60/60/30 60/60/30
GA 7 575 CSA/UL 15.5 20 25
GA 11 200 CSA/UL 63.5 80 80
GA 11 200/230/460 CSA/UL 61/55/27.5 80/80/40 80/80/40
GA 11 575 CSA/UL 22 30 35
11.4 Dryer switches
General
The regulating and safety devices are factory-adjusted to give optimum performance of the dryer.
Do not alter the setting of any of the devices.
11.5 Reference conditions and limitations
Reference conditions
Air inlet pressure (absolute) bar 1
Air inlet pressure (absolute) psi 14.5
Air inlet temperature ˚C 20
Air inlet temperature ˚F 68
Relative humidity % 0
Working pressure See section Compressor data