Limits
Maximum working pressure See section Compressor data
Minimum working pressure bar(e) 5.5
Minimum working pressure psig 80
Maximum air inlet temperature ˚C 46
Maximum air inlet temperature ˚F 115
Minimum air inlet temperature ˚C 0
Minimum air inlet temperature ˚F 32
11.6 Compressor data
Reference conditions
All data specified below are valid at reference conditions, see section Reference conditions
and limitations.
GA 5
Units 7.5 bar 8.5 bar 10 bar 13 bar 100 psi 125 psi 150 psi 175 psi
Frequency Hz 50 50 50 50 60 60 60 60
Maximum
(unloading)
pressure, units
without dryer
bar(e) 7.5 8.5 10 13 7.4 9.1 10.8 12.5
Maximum
(unloading)
pressure, units
without dryer
psig 109 123 145 189 107 132 157 181
Maximum
(unloading)
pressure, Full-
Feature units
bar(e) 7.25 8.25 9.75 12.75 7.15 8.85 10.55 12.25
Maximum
(unloading)
pressure, Full-
Feature units
psig 105 120 141 185 104 128 153 178
Nominal working
pressure
bar(e) 7 8 9.5 12.5 6.9 8.6 10.3 12
Nominal working
pressure
psig 102 116 138 181 100 125 150 175
Pressure drop over
dryer, Full-Feature
units
bar(e) 0.10 0.08 0.05 0.02 0.10 0.08 0.05 0.02