Type V Approval Recommended wire section (AWG)
Pack Full Feature
GA 5 200 CSA/UL 8 8
GA 5 200/230/460 CSA/UL 8 8
GA 5 575 CSA/UL 14 12
GA 7 200 CSA/UL 8 6
GA 7 200/230/460 CSA/UL 8 6
GA 7 575 CSA/UL 12 10
GA 11 200 CSA/UL 4 4
GA 11 200/230/460 CSA/UL 4 4
GA 11 575 CSA/UL 10 10
11.3 Settings for overload relay and fuses
Overload relay and fuses
Type V Approval Overload Relay
Pack
Overload Relay
Full Feature
MAX Setting (A) MAX Setting (A)
GA 5 200 IEC 40 32 40 39
GA 5 230 IEC 28 28 40 32
GA 5 380 IEC 20 16 25 19
GA 5 400 IEC 20 16 25 19
GA 5 400 + N IEC 20 16 25 21
GA 5 460 IEC 20 15 20 17
GA 5 500 IEC 16 14 20 16
GA 7 200 IEC 50 42 50 48
GA 7 230 IEC 40 36 50 41
GA 7 380 IEC 25 21 32 24
GA 7 400 IEC 25 21 32 24
GA 7 400 + N IEC 25 21 32 26
GA 7 460 IEC 25 19 25 21
GA 7 500 IEC 20 19 25 20
GA 11 200 IEC 63 60 80 68
GA 11 230 IEC 63 52 63 59
GA 11 380 IEC 32 30 40 34
GA 11 400 IEC 32 30 40 34
Instruction book