If one of the measurements exceeds the programmed shut-down warning level, this will also be indicated to
warn the operator before the shut-down level is reached.
Service warning
If the service timer exceeds a programmed value, this will be indicated on the display to warn the operator to
carry out some service actions.
Automatic restart after voltage failure
The regulator has a built-in function to automatically restart the compressor when the voltage is restored after
voltage failure. This function is deactivated in compressors leaving the factory. If desired, the function can
be activated. Consult the Atlas Copco Customer Centre.
If activated, and if the regulator was in the automatic operation mode, the compressor will
automatically restart when the supply voltage to the module is restored!
3.2 Control panel
Detailed description
Control panel of the Elektronikon with standard display
Reference Designation Function
1 Display Shows icons and operating conditions.
2 Automatic operation symbol
3 LED, Automatic operation Indicates that the regulator is automatically controlling the
compressor: the compressor is loaded, unloaded, stopped
and restarted depending on the air consumption and the
limitations programmed in the regulator.
4 Warning symbol
5 LED, Warning Is lit if a warning condition exists.
6 Voltage symbol
7 LED, Voltage on Indicates that the voltage is switched on.
8 Service symbol