7.3 Starting
Procedure
For the position of the air outlet valve and the drain connections, see sections Introduction
and Condensate system
Control panel of the Elektronikon® controller
Control panel of the Elektronikon® Graphic controller
Step Action
- Switch on the voltage. Check that voltage on LED (6) lights up.
- Open the air outlet valve.
- Close the condensate drain valve(s) (Dm).
- Press start button (1) on the control panel. The compressor starts running and the automatic
operation LED (8) lights up. Ten seconds after starting, the drive motor switches over from star
to delta and the compressor starts running loaded.