Dewpoint temperature
3.4 Main screen
When the voltage is switched on, the first screen is a test screen. The next screen is the Main screen, shown
automatically.
The Main screen shows:
• The compressor status by means of pictographs
• The air outlet pressure
Always consult Atlas Copco if the pressure on the display is preceded by a "t".
3.5 Shut-down warning
Description
A shut-down warning will appear in the event of:
• Too high a temperature at the outlet of the compressor element
• Too high a dewpoint temperature (Full-Feature compressors)
Compressor element outlet temperature
• If the outlet temperature of the compressor element exceeds the shut-down warning level (factory set at
110 ˚C / 230 ˚F), warning LED (5) starts blinking.