Important remark:
In the Elektronikon you can select different timers on one day.(up to 8 actions). It is
however not possible to program 2 actions at the same time. The solution: leave at least
1 minute in between 2 actions.
Example: Start Compressor: 5.00 AM, Pressure Setpoint 2: 5.01 AM (or later).
Procedure
Starting from the Main screen (see Main screen),
• Move the cursor to the action button Menu and press the Enter key. Use the Scroll buttons to select the
Timer icon.
Text on figure
(1) Menu
(2) Week Timer
• Press the Enter key on the controller. Following screen appears:
(1) Week Timer
(2) Week Action Schemes
(3) Week Cycle
(4) Status
(5) Week Timer Inactive
(6) Remaining Running Time
The first item in this list is highlighted in red. Select the item requested and press the Enter key on the
controller to modify.
Instruction book
2920 7109 60 99