Unloading valve/blow-off valve (UV) moves upwards, connecting the oil separator tank pressure (1) with
channels (2) and (3).
The pressure in channel (2) causes the loading plunger (LP) to move upwards, causing inlet valve (IV) to
close, while the pressure is gradually released to atmosphere.
The pressure in the separator tank stabilises at low value. A small amount of air is kept drawn in to
guarantee a minimal pressure, required for lubrication during unloaded operation.
Air output is stopped, the compressor runs unloaded.
2.7 Electrical system
Electrical components
The electrical system comprises following components:
Typical Example of electric cubicle on GA 55
+
up to GA 90
Reference Designation
F1/2/3 Fuses
F7/F8/F9 Fuses (only on Full-Feature)
F21 Overload relay, compressor motor
Q15 Circuit breaker, fan motor (on air-cooled compressors)
K5 Auxiliary relay
K11 Auxiliary contactor
K12 Auxiliary contactor
K15 Auxiliary contactor, fan motor (on air-cooled compressors)
K21 Line contactor
K22 Star contactor
K23 Delta contactor