3.21 Calling up/modifying service timer settings
Control panel
Starting from the Main screen:
Press Scroll button (12) until <P. 6> is shown and then press Enter button (13): the setting of the service
timer is shown in <hrs> (hours) or <x1000 hrs> (hours x 1000). Example: <4000 hrs> means the timer is
set at 4000 running hours.
Press Enter button (13) to modify this value (a password may be required): the value blinks. Use the Scroll
buttons (12) to modify the setting.
Press Enter button (13) to program the new value.
3.22 Calling up/modifying the unit of temperature
Control panel
Starting from the Main screen:
Press Scroll button (12) until <P.07> is shown and then press Enter button (13). The actually used unit is
shown. Possible settings are <˚C> and <˚F>.
Press Enter button (13) (unit blinks) and use the Scroll buttons (12) to select another unit of temperature.
Press Enter button (13) to program the new unit or press Escape button (14) to return to the parameter
screen without changes.