OSCi air injection
1 Aftercooler (WSD in case of a water-cooled
compressor)
4 Strainer
2 Air tube to OSCi vessel 2 5 Y-connection
3 Solenoid valve 6 Air tube to EWD
Automatic as well as manual safety devices to prevent overflow are present. Besides the automatic overflow
switch (7-View of OSCi), which is mounted in a side-chamber on the second vessel and gives an alarm when
condensate level is too high, the customer can check for high condensate level through the sight glass. On a
case-by-case basis, it can be decided to automatically shut down the compressor in case of an overflow alarm.
When overflow occurs, the resulting waste water must be treated as oil-containing water and must be disposed
of according to local regulations.