Flow diagram, GA Workplace Full-Feature
Reference Description
A Intake air
B Air/oil mixture
C Oil
D Wet compressed air
E Condensate
F Dried compressed air
Note: The cooling fan is not provided on water-cooled compressors.
Description
Air drawn through filter (AF) and open inlet valve (IV) of unloader is compressed in compressor element (E).
A mixture of compressed air and oil flows into the air receiver/oil separator (AR) via check valve (CV). The
air is discharged through outlet valve (AV) via minimum pressure valve (Vp) and air cooler (Ca).
The air cooler is provided with a moisture trap (MT).
On Full-Feature compressors, the air flows through air dryer (DR) before it is discharged through outlet valve
(AV). Also see section Air dryer.
Instruction book
2920 7109 60 17