7.5 bar 8.5 bar 10 bar 13 bar 100 psi 125 psi 150 psi 175 psi
Pressure dew point,
Workplace Full-Feature
units
˚F 37.4 37.4 37.4 37.4 37.4 37.4 37.4 37.4
Temperature of air
leaving outlet valve,
Workplace Full-Feature
units
˚C 23 23 23 23 23 23 23 23
Temperature of air
leaving outlet valve,
Workplace Full-Feature
units
˚F 73.4 73.4 73.4 73.4 73.4 73.4 73.4 73.4
Dryer power at full load,
Workplace Full-Feature
units
kW 2.4 2.4 2.4 1.6 2.6 2.6 2.6 1.6
Dryer power at full load,
Workplace Full-Feature
units
hp 3.22 3.22 3.22 2.15 3.49 3.49 3.49 2.15
Dryer power at no load,
Workplace Full-Feature
units
kW 2.1 2.1 2.1 1.4 2.3 2.3 2.3 1.4
Dryer power at no load,
Workplace Full-Feature
units
hp 2.82 2.82 2.82 1.88 3.08 3.08 3.08 1.88
Refrigerant type,
Workplace Full-Feature
units
R410A R410A R410A R410A R410A R410A R410A R410A
Refrigerant quantity,
Workplace Full-Feature
units
kg 1.1 1.1 1.1 1.05 1.2 1.2 1.3 1.05
Refrigerant quantity,
Workplace Full-Feature
units
lb 2.43 2.43 2.43 2.31 2.65 2.65 2.87 2.31
Cooling water
consumption (at water
inlet temperature below
35 ˚C and temperature
rise of 15 ˚C), water-
cooled units
l/min 90 90 90 90 90 90 90 90
Cooling water
consumption (at water
inlet temperature below
95 ˚F and temperature
rise of 27 ˚F), water-
cooled units
cfm 3.18 3.18 3.18 3.18 3.18 3.18 3.18 3.18
Cooling water
consumption (at water
inlet temperature
between 35 and 40 ˚C
and temperature rise of
10 ˚C), water-cooled units
l/min 130 130 130 130 130 130 130 130