Oil or grease escapes from the ContiLube
®
II
Cause Remedy By
Connecting fittings are loose Check the connecting fittings and tighten
(see chapter Bolt connections/Tightening torques)
Workshop
Operating temperature too high
Cause Remedy By
Oil level in tank too low Check the oil level and top up oil Carrier driver or workshop
Carrier pump delivery too high; a constant
volume of oil is squirted out of the
pressure relief valve
Check carrier engine speed and lower Carrier driver
Check carrier settings and adjust Atlas Copco Customer
Center/Dealer in your area
Operation in high outside temperature
without oil cooler
Check oil temperature and install an oil cooler if required Workshop or Atlas Copco
Customer Center/Dealer in
your area
Pressure relief valve defective or valve
with poor characteristic
Fit new type-tested pressure relief cartridges or a more
precise pressure-limiting valve
Workshop
Pressure line »P« flails violently
Cause Remedy By
There is a problem with the HP-
accumulator operation
Immediately stop the hydraulic breaker.
The HP-accumulator needs to be checked by a
professional
Workshop
HB 2000, 2000 DP, 2500, 2500 DP Safety and operating instructions
© Construction Tools GmbH | 3390 5090 01 | 2016-05-23
Original instructions
61