EasyManuals Logo

Atlas Copco HiLight H6+ Kd ESF User Manual

Atlas Copco HiLight H6+ Kd ESF
116 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #73 background imageLoading...
Page #73 background image
- 73 -
7.4.14 Roadlights for right hand
driving
7.4.15 Auto mast down
The ASM option provides the possibility to not only
switch on/off the floodlights automatically, but also
to extend/lower the mast automatically.
To enable automatic mast operation, proceed as
follows:
For cubicle with Lc1003™ controller
1. Put the starter switch S20 in position REMOTE.
2. Switch ON the 4 circuit breakers (Q2-5).
3. Put the auto positioning switch S25 in position
AUTO.
4. Push the AUTO button on the Lc1003™ module
(1) to activate AUTO mode.
5. A remote start signal (Sunset or Weekly timer
start) will trigger the following actions:
Start engine
Activate buzzer
•Rise mast
Sequence lamp start
6. A remote stop signal (Sunrise or Weekly timer
stop) will trigger the following actions:
Sequence lamp stop
Activate buzzer
•Lower mast
Stop engine
For cubicle with Lc1001™ controller
The Auto Mast Down function is always enabled.
The power of the hydraulic pump
for the mast is 850 W. Therefore it is
only possible to extend/lower the
mast if the power on the auxiliary
sockets is below 1800 W.
Before activating the ASM option,
make sure that the lighting tower is
properly positioned, away from
overhead power cables or other
obstructions.
S50
S51
S20
0
1
H16
Q2 Q3 Q4 Q5Q1 Q6
P7
AUTO MAN
F10
AUTO MAN
Q2-5
S20
1
S25
00_00_HiLight H6+_EN.book Page 73 Friday, June 4, 2021 11:52 AM

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Atlas Copco HiLight H6+ Kd ESF and is the answer not in the manual?

Atlas Copco HiLight H6+ Kd ESF Specifications

General IconGeneral
BrandAtlas Copco
ModelHiLight H6+ Kd ESF
CategoryLighting Equipment
LanguageEnglish

Related product manuals