5.5 During operation
Control panel
Procedure
When automatic operation LED (1) is alight, the Elektronikon regulator is automatically controlling the
compressor: the air delivery is matched to the air consumption, the compressor will start and stop whenever
necessary.
Avoid short compressor loading periods (minimum 50% load) and operation at very low working pressures
as otherwise the performance of the dryer will diminish. Avoid operation at too low a regeneration air
temperature (minimum 130˚C /266˚F)
Keep all doors closed during operation.