3.22 Programmable settings
Parameters
Minimum
setting
Factory
setting
Maximum
setting
Motor running time in star sec 10 10 30
Load delay time (star-delta) sec 10 10 30
Number of motor starts starts/day 0 240 240
Minimum stop time sec 20 20 99
Programmed stop time sec 3 3 20
Power recovery time (ARAVF) sec 15 15 3600
Restart delay sec 0 3 255
Communication time-out sec 10 20 60
Unloading pressure bar(e) 4.5 7.0 7.25
Unloading pressure psig 65 101.5 105.2
Unloading pressure bar(e) 4.5 7.0 7.5
Unloading pressure psig 65 101.5 108.8
Unloading pressure bar(e) 4.5 8.0 8.6
Unloading pressure psig 65 116 124.7
Unloading pressure bar(e) 4.5 8.0 9.0
Unloading pressure psig 65 116 130.5
Unloading pressure bar(e) 4.5 9.0 10..0
Unloading pressure psig 65 130.5 145
Unloading pressure bar(e) 4.5 9.0 10.4
Unloading pressure psig 65 130.5 150.8
Loading pressure bar(e) 4.5 6.5 7.25
Loading pressure psig 65 94.3 105.2
Loading pressure bar(e) 4.5 6.5 7.5
Loading pressure psig 65 94.3 108.8
Loading pressure bar(e) 4.5 7.5 8.6
Loading pressure psig 65 108.8 124.7
Loading pressure bar(e) 4.5 7.5 9.0
Loading pressure psig 65 108.8 130.5
Loading pressure bar(e) 4.5 8.0 10..0
Loading pressure psig 65 116 145
Loading pressure bar(e) 4.5 8.0 10.4
Loading pressure psig 65 116 150.8