4.3 Electric cables
Remarks
The cable sizes below are applicable for the MAINS + EARTH CABLE
The cable size is valid at maximum ambient temperature of 40 ˚C.
The cable size is valid at maximum ambient temperature of 104 ˚F.
50Hz IEC
Pack and Full-Feature compressors
400 V
ZT/ZR55
3 x 50 + 25 mm
2
ZT/ZR75
3 x 95 + 50 mm
2
ZT/ZR90
3 x 120 + 70 mm
2
Full-Feature ND compressors
400 V
ZT/ZR55
3 x 70 + 35 mm
2
ZT/ZR75
3 x 70 + 35 mm
2
ZT/ZR90 2x (3 x 50 + 50
mm)
2
Full-Feature ND compressors
Instruction book
85
380 V 440-460 V
ZT/ZR55
3 x 70 + 35 mm
2
3 x 70 + 35 mm
2
ZT/ZR75 2x (3 x 50+ 35
mm)
2
3 x 70 + 35 mm
2
ZT/ZR90 2x (3 x 70+ 35)
mm
2
2x (3 x 50 + 25
mm)
2