• 06:00 Pressure Band 1
• 18:00 Stop Compressor
The regulator does not allow to enter a new command which is situated before the last command in the list
timewise.
Scroll through the display until the command before which the new command must be entered is followed
by a horizontal arrow (in the example above: “18:00 Stop Compressor”) and press the key “Modify”.
Change this command to the new command (in the example above “17:00 Pressure Band 2”)
Press the arrow down key and add the last command of the list (in the example above “18:00 Stop Compressor”
and press the key “Program”.
Deleting a command
• Starting from the Main screen, press the key “Menu” (F1), press the arrow down key until the option
“Modify Parameters” is followed by a horizontal arrow.
• Activate the menu by pressing the tabulator key (2).
• Use the scroll keys (1) to scroll until the option “Clock Function” is followed by a horizontal arrow. Press
the tabulator key, following screen appears:
“Clock Function”
“Not Activated”
.
“Menu” “Modify” “Delete”
F1 F2 F3
Deleting all commands
• Press the key “Delete” in the screen above. A question to confirm the deleting operation will appear.
Deleting all commands of a specific day
• Scroll through the display until the desired day is followed by a horizontal arrow. Press the key “Delete”,
a question to confirm the deleting operation will appear.
Deleting a specific command
• Scroll through the display until the command to be deleted is followed by a horizontal arrow. Press the
key “Delete”, a question to confirm the deleting operation will appear.
Instruction book